Sample application | 简体中文
Drive Signal and Interface Power Management
How is the channel current set for SiLM4228x (x=0, 1, 2, 3)?

The setting of channel current for SiLM4228x (x=0, 1, 2, 3) is as follows:

1. Divide 1.5V by the resistance of IRx (x=1, 2, 3) pins to obtain a current;

2. Multiply the current obtained above by 960 times to obtain the corresponding channel current.

What are the differences between SiLM4228x (x=0, 1, 2, 3) products?

SiLM4228x (x=0, 1, 2, 3) has identical parameters except for the Open diagnostic enable threshold.

Can the Clamp pin in SiLM5350 be suspended when not in use?

It is recommended to connect to the VEE2 pin. During normal use, connect to the OUT pin. The Clamp function triggers clamping by adjusting the voltage of the clamp pin itself. When the clamp voltage is below 2V, the Vclamp is pulled down to VEE2.

How should the DT foot in SLMi8233 be connected?

It is recommended to add a resistor and a capacitor (2.2nF is recommended) to maintain the stability of the DT voltage, so as to ensure that the DT time from channel A to channel B and from channel B to channel A is equal.

How should the VSS pin and COM pin of SLM21814 be connected?

It is recommended to short connect the VSS pin to COM, with a pressure difference of no more than 5V.

How should the VLED pin in SLMi33x be connected?

It is recommended to connect the VLED pin to the VEE (not VE).

What is the difference between SLM8833 and SLM8834?

Two zero drift operational amplifiers are integrated in SLM8834, which can be used for analog PID control. However, SLM8833 does not integrate these two operational amplifiers and can only be controlled using digital PID.